Last edited by Akinoran
Thursday, July 16, 2020 | History

2 edition of Dry Pipe and Deluge Valves for Fire-Protection Service, UL 260 (Standard for Safety UL / Underwriters Laboratories) found in the catalog.

Dry Pipe and Deluge Valves for Fire-Protection Service, UL 260 (Standard for Safety UL / Underwriters Laboratories)

Underwriters Laboratories

Dry Pipe and Deluge Valves for Fire-Protection Service, UL 260 (Standard for Safety UL / Underwriters Laboratories)

by Underwriters Laboratories

  • 129 Want to read
  • 16 Currently reading

Published by Underwriters Laboratories, Incorporated .
Written in English

    Subjects:
  • Engineering - Electrical & Electronic,
  • Technology & Industrial Arts

  • The Physical Object
    FormatPaperback
    ID Numbers
    Open LibraryOL12096448M
    ISBN 101559895845
    ISBN 109781559895842

    SPECIAL SYSTEM WATER CONTROL VALVES, DELUGE TYPE See Addendum Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: UL , Standard for Dry Pipe and Deluge Valves for Fire Protection Service ULC-ORD-C , Guide for the Investigation of Dry. This standard does not provide specific design guidance for dry pipe or double interlock preaction systems. * This standard shall not apply to water spray protection from portable nozzles, sprinkler systems, monitor nozzles, water mist suppression systems, explosion suppression, or other means of application covered by other standards of.

    Deluge Valve is known as a system control valve in a deluge system, used for fast application of water in a spray system. Deluge valve protects areas such as power transformer installation, storage tank, conveyor protection and other industrial application etc. With the addition of foaming agent, deluge valveFile Size: 1MB. Everything you need to know about Deluge Valves. They are commonly used in fixed fire protection systems whose pipe system is empty until the deluge valve distributes pressurised water from open nozzles or sprinklers. Deluge systems contain more components and equipment than wet pipe and dry systems. So for that matter they are more complex.

    Deluge Fire Sprinkler System; Deluge Fire Sprinkler System. A deluge fire sprinkler system is similar to a pre-action system except the sprinkler heads are open and the pipe is not pressurized with air. Deluge systems are connected to a water supply through a deluge valve that is opened by the operation of a smoke or heat detection system.   Author of Communications Cables, UL (Csa Standard,), Diesel Engines for Driving Centrifugal Fire Pumps, UL (Standard for Safety /Underwriters Laboratories Inc.), Dry Pipe and Deluge Valves for Fire-Protection Service, UL (Standard for Safety UL / Underwriters Laboratories), Low-Voltage Fuses PT. 12, Ducted Heat Recovery Ventilators, UL .


Share this book
You might also like
Handbook of professional ethics for psychologists

Handbook of professional ethics for psychologists

Building the health bridge

Building the health bridge

Dick Knox at LeMans

Dick Knox at LeMans

Rescued from the river!

Rescued from the river!

complete works of Robert Browning.

complete works of Robert Browning.

In a spirit of socialist internationalism and friendship

In a spirit of socialist internationalism and friendship

Mother Light

Mother Light

What not

What not

[Execution of Louis Riel]

[Execution of Louis Riel]

Edinburgh International Festival 1985.

Edinburgh International Festival 1985.

The childs present

The childs present

Textiles - standard atmospheres for conditioning and testing.

Textiles - standard atmospheres for conditioning and testing.

Baby Angels Wear Em Award Badges 30 Per Package

Baby Angels Wear Em Award Badges 30 Per Package

Ward pocket book for the nurse

Ward pocket book for the nurse

Bio-hydro-engineering

Bio-hydro-engineering

Dry Pipe and Deluge Valves for Fire-Protection Service, UL 260 (Standard for Safety UL / Underwriters Laboratories) by Underwriters Laboratories Download PDF EPUB FB2

Differential type dry pipe valves; Latched-clapper type dry pipe valves; Deluge valves; 9 Bodies and Covers; 10 Valve Mechanisms; General; Clapper supports; 11 Anti-Reseat Latches; 12 Clapper Stops; 13 Clapper Rings and Seat Rings; 14 Clearances; 15 Valve Settings; 16 Valve Gags; 17 Priming Water; 17A Valve Trim Accessories.

FOR. Dry Pipe and Deluge Valves for Fire-Protection Service. UL ; 7th Ed; Revised July 3, This summary is derived from Standard Development Organization (SDO) bulletin(s) or other documentation publicly available. Find the most up-to-date version of UL at Engineering DRY PIPE AND DELUGE VALVES FOR FIRE-PROTECTION SERVICE.

Dry Pipe and Deluge Valves for Fire-Protection Service UL Dry Pipe and Deluge Valves for Fire-Protection Service. This new edition of ANSI/UL is a periodic re-issuance to ensure that UL's Standards remain up-to-date with regard to format and editorial issues such as renumbering, paginating, correction of editorial errors.

UL Standard for Safety Dry Pipe and Deluge Valves for Fire-Protection Service These requirements cover valve equipment intended for installation in piping systems to supply water automatically to dry pipe, deluge, and preaction sprinkler systems for fire-protection service. UL Ma Standard for Dry Pipe and Deluge Valves for Fire-Protection Service: 7: ulstd: ansi: A: Outline of Investigation for Air Pressure Maintenance Devices: 1: outline: A: Standard for Gate Valves for Fire-Protection Service: 8: ulstd: Standard for Fire Tests of Building.

Rated for use at a maximum service pressure of psi (17,2 bar) Listings and Approvals: UL, C-UL, and FM NYC under MEA E (4 and 6 inch) Tech Data Sheet: View TFP Tech Data Translations [PDF]: LV, SV. #N#TYCO® DPV-1 Installation Overview. TYCO® DPV-1 Dry Pipe Valve Installation - YouTube.

Tyco Fire Products. K subscribers. UL-listed and/or FM-approved residential and commercial fire sprinkler heads, check valves, hose angle valves, CPVC pipe, pipe hangers, and fire extinguishers are just part of our vast catalog of certified equipment—just take a look.

UL is a global independent safety science company offering expertise across three strategic businesses: Commercial & Industrial, Consumer and UL Ventures. Our breadth, established objectivity and proven history mean we are a symbol of. Outdoor and Indoor Integrated Fire Protection Package, Electric Actuation.

Note: Europe & Middle East Product. Vertical or Horizontal, Diaphragm Style, psi, /2" thru 8" Aluminum Bronze Deluge Valve. Diaphragm Style, psi, 2" thru 8" DV-5 Deluge Valve, Diaphragm Style, /2" thru 8" (DN40 thru DN), Deluge System - Wet Pilot Actuation.

Standard(s) for Safety: ULDry Pipe and Deluge Valves for Fire-Protection Service Additional Information: See the UL Online Certifications Directory at. the deluge valve has actuated, immediately close the upstream side stop valve. (iv)Once testing is over reset the valve as per procedure given under heading “RESETTING PROCEDURE FOR THE DELUGE VALVE”.

INSPECTION AND MAINTENANCE All the newly installed system piping network must be flushed properly before placing the deluge valve in Size: 1MB.

DRY PIPE AND PREACTION SPRINKLER SYSTEM - SECTION 1. PART 1 - GENERAL D. Equipment for fire protection service shall be UL listed or FM approved for use in [wet and] dry pipe alarm valves, dry-pipe valve and deluge valve assemblies waterflow and tamper switches, backflow preventers, and other trim furnished.

The deluge valves are mainly used to control the flow of water or water/foam solution in fixed fire suppression, cooling or gas containment systems.

Depending on the project requirements, there are several possible flow control activation options that include electric, electro-pneumatic and hydraulic on which additional features such as. Pipe and Deluge Valves for Fire Protection Service, ULSeventh Edition and the Guide for the Investigation of Dry Pipe and Deluge and Pre-Action Valves for Fire Protection Service, ULC/ORD C, Issue No.

2., in effect as of the date of this Report. Inbal Valves are advanced control valves for fire protection systems in: oil & gas, offshore, power generation, chemical industries.

Including: approved deluge, remote control, pressure & flow control, dry pipe, preaction valves. Then contact customer service at UL now developing Standards for the Canadian Market (click here for list) Standard for Dry Pipe and Deluge Valves for Fire-Protection Service UL Standard.

Scope StandardEdition 7 Edition Date: Ma ANSI Approved: July Then contact customer service at UL now developing Standards for the Canadian Market (click here for list) Standard for Dry Pipe and Deluge Valves for Fire-Protection Service UL Revision. Scope Standard.

Placing the Valve in Service For Deluge Valves equipped with Conventional Deluge Valve Trim, follow steps 1 through 10 (and 11 & 12 if applicable) below.

Verify: a. The system Main Water Supply Control Valve (D.1) is closed and the Deluge Valve is trimmed according to current Viking Trim Charts and schematic drawings for the system used.

BERMAD deluge valves are designed in compliance with the UL safety standard for dry pipes and deluge valves for fire-protection services. Moreover, BERMAD has set its acceptance criteria much higher than the UL standard requires. Our internal standard requires tight shut off (TSO) for our deluge valves.

based fire protection systems. These valves are used to shut off water to main systems. Control valves do not include hose valves, inspectors test valves, drain valves, trim valves for dry pipe, preaction and deluge valves, check valves or relief valves.

The main con-trol valve is located below the dry pipe valve. ThisFile Size: 1MB. All deluge valves are self-operated water driven valves. The primary function of the Solenoid Valve is to release the control valve. Every electrically operated deluge valve shall be certified by Underwriter Laboratories (UL) and/or FM Global (FM) and must be listed with a specific solenoid according to the standard.

The UL and FM standards are very strict and must. The deluge valve Model VDD is an innovative concept valve designed for fire protection systems according to N UL and IEC / The VDD deluge valve combines all the functions.